DailyDoctor Archive Specialties Get app
Back to the 22 October 2026 edition

Clinical update · 01 of 05

A mandibular advancement appliance came close to CPAP on desaturations in CPAP-intolerant patients

For mild to moderate OSA in patients who will not use CPAP, consider a mandibular advancement device and confirm its effect with a follow-up sleep study.

Design
Crossover clinical study
Population
20 adults with OSA (AHI below 50) who had not adhered to CPAP
Primary outcome
Oxygen desaturation index, snoring and hypoxic burden on home sleep testing
Effect
Median ODI 13.6 untreated, 6.1 with appliance, 5.3 with CPAP (appliance vs CPAP p = 0.40)

Twenty adults with obstructive sleep apnoea confirmed by polysomnography (AHI below 50 events per hour), all of whom had not adhered to CPAP, were fitted with a mandibular advancement appliance made through a fully digital workflow. Each then had home sleep tests untreated, on CPAP and on the appliance, in a crossover design.

Median oxygen desaturation index fell from 13.6 events per hour untreated to 6.1 with the appliance and 5.3 with CPAP; the difference between treatments was not significant. Snoring, hypoxic burden and heart rate also did not differ, while mean oxygen saturation was slightly better on CPAP.

This is a small study, published in an orthodontic journal, and it used home tests rather than full polysomnography after treatment. It fits existing evidence that mandibular devices are a reasonable option for mild to moderate OSA, especially when CPAP is not used. It cannot show equivalence, and in severe OSA CPAP remains first line.

  • Consider a mandibular advancement device for mild to moderate OSA when CPAP is not tolerated.
  • Confirm efficacy with a sleep study on the device after titration.
  • Refer to a dentist experienced in sleep appliances for fitting and follow-up.
  • Keep CPAP as first line for severe OSA or marked daytime sleepiness.
  • A device used every night may do more than CPAP used rarely.

Why it matters

CPAP intolerance often ends treatment altogether; a credible alternative keeps patients treated.

Don't overread it

Twenty patients and a non-significant difference cannot establish that the device is as good as CPAP.

The statistics, in plain English

A p value of 0.40 for the difference in desaturation index means no difference was detected, not that none exists. With only 20 people, the study could miss a clinically important gap.

Read the rest in the app

You have read your two free briefings this month. The app carries all 27 specialties, every morning, free — and this finding is waiting in it.

QR code to install Daily Doctor
Get Daily Doctor — free

Scan to keep reading on your phone. No account needed to start.

sleepcopdrespcriticalild

Tomorrow morning, before your first patient

One edition a day for pulmonology, written by the desk, every claim tied to its paper. Six minutes.

Get the app — free
Daily Doctor All 27 specialties, every morning. Free.
Get the app