Dual-phase angio-CT in liver procedures did not raise patient dose

When a hybrid suite offers angio-CT for intra-arterial liver procedures, choose it on image quality; it did not increase patient dose.

Design
Single-centre retrospective comparison
Population
92 intra-arterial liver procedures: 48 cone-beam CT, 44 dual-phase angio-CT
Primary outcome
Patient effective dose (2D, 3D and total)
Effect
3D dose median 9.85 vs 39.9 mSv (p < 0.001); total 34.6 vs 55.9 mSv (corrected p = 0.053)

Hybrid angiography suites with an integrated CT scanner give better images than C-arm cone-beam CT during intra-arterial liver procedures, but there has been concern that they add radiation. A retrospective European Radiology study compared 92 bland embolisation and radioembolisation mapping procedures performed with single-phase cone-beam CT (48) or dual-phase angio-CT (44).

Fluoroscopy dose was similar. The 3D imaging dose was about four times lower with angio-CT (median 9.85 against 39.9 mSv, p < 0.001), and total effective dose was 34.6 against 55.9 mSv. After correcting for uncertainty in dose conversion, the 3D reduction remained significant but the total dose difference did not (p = 0.053).

For interventional radiologists choosing between the two, the conclusion is that angio-CT does not carry a dose penalty and may lower 3D dose, so image quality can drive the choice where both are available. This is a single-centre retrospective comparison with differing case mix.

  • Where available, angio-CT can be used for intra-arterial liver procedures without concern for added patient dose.
  • 3D imaging dose was about four times lower with dual-phase angio-CT than with single-phase cone-beam CT.
  • Total procedural dose was not higher with angio-CT and may be lower.
  • Record dose metrics for each procedure to support local optimisation.

Why it matters

A perceived radiation penalty has been one reason to hesitate over angio-CT; this study did not find one.

Don't overread it

The total dose reduction lost significance after uncertainty correction, so claim no increase rather than a decrease.

The statistics, in plain English

A p-value of 0.053 after correction sits just above the usual threshold, so the total dose saving may be real but is not proven. The 3D dose difference is robust.

Read the rest in the app

You have read your two free briefings this month. The app carries all 27 specialties, every morning, free — and this finding is waiting in it.

QR code to install Daily Doctor
Get Daily Doctor — free

Scan to keep reading on your phone. No account needed to start.

breastimagingimagingaineuroimaginginterventional

Tomorrow morning, before your first patient

One edition a day for radiology, written by the desk, every claim tied to its paper. Six minutes.

Get the app — free
Daily Doctor All 27 specialties, every morning. Free.
Get the app