DailyDoctor Archive Specialties Get app
Back to the 20 October 2026 edition

Practice changer · 05 of 05

Routine high-level disinfection of tonometer tips and clinic lenses is not required, says a multisociety task force

Routine high-level disinfection of tonometer tips and diagnostic lenses is not required in the task force's view; reserve it for higher-risk cases such as suspected infection.

Regulators in the US and elsewhere have increasingly cited clinics for not applying high-level disinfection to Goldmann tonometer tips, gonioscopy lenses, laser lenses and similar reusable devices that touch the ocular surface. A multisociety task force reviewed the evidence (Ophthalmology, 9 October 2026); its summary recommendations come from a policy statement approved by the American Academy of Ophthalmology board and endorsed by four subspecialty societies.

The task force found no published evidence that these devices transmit sight-threatening infection, or that high-level disinfection reduces transmission compared with lower-level methods. In its survey of more than 1,000 ophthalmologists, alcohol wiping was the commonest method for tonometer tips, and alcohol or soap and water for lenses; many who used chemical high-level disinfection reported ocular surface chemical toxicity and device damage. Reported transmission was very rare and mostly self-limiting adenoviral conjunctivitis. The authors argue the century-old Spaulding classification wrongly groups the ocular surface with heavily contaminated mucous membranes.

The recommendation is that high-level disinfection should not be required in routine care, and should be a discretionary step in higher-risk situations, such as after use on a patient with suspected infection.

  • Use your established lower-level cleaning method, such as an alcohol wipe, for tonometer tips and lenses in routine care, following local infection-control policy.
  • Apply high-level disinfection, or use a disposable tip, after examining a patient with suspected adenoviral or other ocular infection.
  • Rinse and dry devices fully after any chemical disinfectant to avoid corneal toxicity.
  • Inspect reusable tips and lenses for damage from repeated chemical exposure.
  • Where local regulators still mandate high-level disinfection, follow the regulation while it stands.

Why it matters

It challenges a regulatory mandate that adds cost, waste and chemical injury without evidence of preventing infection.

Don't overread it

This is a professional position statement based on absence of evidence and a survey, not a trial; local regulations still apply.

Read the rest in the app

You have read your two free briefings this month. The app carries all 27 specialties, every morning, free — and this finding is waiting in it.

QR code to install Daily Doctor
Get Daily Doctor — free

Scan to keep reading on your phone. No account needed to start.

corneaglaucoma

Tomorrow morning, before your first patient

One edition a day for ophthalmology, written by the desk, every claim tied to its paper. Six minutes.

Get the app — free
Daily Doctor All 27 specialties, every morning. Free.
Get the app